Innotica
Clinical infrastructure cannot operate blind
Healthcare Sector

Clinical infrastructure cannot operate blind

Mission-critical monitoring for operating rooms, ICU, imaging and medical gases. When every second counts, technology must anticipate.

40%
of total consumption is HVAC
72%
of facilities with chronic failures
20%
energy savings in 3 years
24/7
24/7 Monitoring

The building as an instrument of healing

A smart clinic doesn't just automate lights. It's an ecosystem where every pressure sensor, every oxygen meter and every air controller works in harmony to sustain life.

Explore by area

Each clinical zone has specific needs

Select an area to see the control and monitoring systems Innotica deploys in it.

Operating room with precision climate control systems

Operating Room

Operating Room and Clean Rooms

Highest criticality zone. Requires millimetric control of differential pressure, temperature, humidity and air quality.

Technical requirements

Positive pressure >2.5 Pa relative to corridor
>20 air changes per hour
Temperature 16-24°C per applicable standard
Relative humidity 40-60%
HEPA H13/H14 filtration with saturation monitoring
Platforms Polaris · Pegasus
Intensive Care Unit with centralized monitoring

ICU

Intensive Care Unit

Continuous life support. Environmental and gas variables must be monitored second by second.

Technical requirements

Oxygen, vacuum and medical air monitoring
Multi-channel alarms (mobile, email, screens)
Differential pressure control in isolation
Power backup supervision (UPS + generator)
Nurse call system integration
Platforms Pegasus · Polaris
Imaging area with MRI scanner

Imaging

Imaging and High Technology

The most expensive equipment in the clinic. Requires extreme environmental and electrical stability to operate without degradation.

Technical requirements

Dedicated MRI chiller monitoring
MRI room temperature: 20-24°C, humidity 40-60%
Critical alarms on minimal parameter deviation
Power quality analysis (harmonics, transients)
Automatic transfer switch monitoring
Platforms Polaris · Castor
Clinical laboratory with precise environmental control

Laboratory

Clinical Laboratory

Result accuracy and staff safety. The environment must be stable and gas extraction efficient.

Technical requirements

Temperature control for reagents and samples
Specialized vapor and gas extraction
Fluid monitoring for analytical equipment
Cold chain deviation alerts
Historical records for traceability
Platforms Polaris · Perseo
Patient room with circadian lighting

Patient Rooms

Patient Rooms

Environmental comfort accelerates recovery. HIS integration transforms bed management.

Technical requirements

Individual room climate control
Adjustable circadian lighting
HIS integration for pre-conditioning on admission
Automatic energy-saving mode on discharge
Nurse call system integration
Platforms Pegasus
Hospital mechanical room with backup systems

Facilities

General Services and Backup

The invisible backbone that holds everything together. A failure here impacts the entire institution.

Technical requirements

Generator and substation monitoring
Fuel level and battery supervision
Constant pressure in potable water and process networks
Leak detection with ultrasonic sensors
Reserve tank level monitoring
Platforms Perseo · Pegasus

The invisible problem

Operating without data is operating blind

In mission-critical infrastructure, the time between failure and detection is not a logistical inconvenience. It is a direct threat to human integrity.

Operating room with precision climate control systems
Critical scenario 1

Operating room pressure drops

A saturated HEPA filter reduces airflow. The operating room's positive pressure drops below minimum. The risk of surgical site infection multiplies. Nobody knows until it shows in postoperative statistics.

Room closures + lawsuits

Intensive Care Unit with centralized monitoring
Critical scenario 2

Oxygen drops during surgery

A silent leak in the cylinder manifold depletes the oxygen reserve. The local alarm sounds in a gas room 200 meters from the operating room. The on-call technician was not in the area.

Immediate life-threatening risk

Imaging area with MRI scanner
Critical scenario 3

The MRI enters quench

The MRI chiller fails at 2am. The liquid helium temperature rises. The equipment activates its emergency protection, vaporizes the helium and shuts down. Three weeks out of service and six-figure costs.

Millions in repairs

Before Innotica

“The failure had already happened. Nobody knew.”

The solution

Innotica turns infrastructure into a living, communicating organism

We don't replace your existing systems. We connect them. Through open protocols (BACnet, Modbus, M-Bus), we integrate all your subsystems into a platform that anticipates, alerts and optimizes in real time.

Smart hospital monitoring dashboard

The Innotica ecosystem

Four specialized platforms. One centralized intelligence.

Each product solves a specific subsystem. Together, they form the nervous system of your clinic.

Pegasus

Hospital BMS

The brain of the clinic. Centralizes monitoring of medical gases, energy, access and integrates with your HIS to automate bed management.

HIS + gases + access integration in one dashboard

Polaris

Critical HVAC

Specialized pressure control in operating rooms, HEPA filter saturation, chillers and VRF. ASHRAE 170 compliance guaranteed.

Asepsis guaranteed by data, not assumptions

Castor

Efficiency and Certification

Identifies energy leaks and generates the historical reports needed to obtain LEED, WELL or EDGE certifications for your institution.

Measurable ROI + international certifications

Perseo

Fluids and Pumping

Constant water pressure, reserve tank supervision, leak detection. Sterilization and clinical processes never stop due to supply failure.

Continuity of critical fluid processes

Return on investment

Automation pays for itself

Three dimensions of return that turn technology into financial advantage.

20%

Energy cost reduction

In 3 years, through dynamic HVAC and lighting control based on actual occupancy.

Less expensive than corrective maintenance

Predictive maintenance avoids costly failures and extends the lifespan of high-value equipment.

100%

Traceability for audits

Automatic environmental condition and event history reports for ASHRAE, ISO and COVENIN.

Scalable methodology

Three phases to transform your medical center

Savings from each phase fund the next. No need to transform everything at once.

01

Phase 1

Diagnosis and Critical Monitoring

We deploy Pegasus to supervise medical gases and power backup. Goal: eliminate the operational "blindness" of the highest-risk systems.

02

Phase 2

Control and Energy Optimization

We implement advanced control in operating rooms and ICU with Polaris. Asepsis is guaranteed and Castor's energy savings begin to amortize the investment.

03

Phase 3

Full Integration and Wellness

We connect the BMS with the HIS, automate patient rooms and guide the institution toward LEED/WELL certifications. The clinic learns from its own data.

International standards

Your clinic, certified by the world's best standards

ASHRAE 170

ASHRAE 170 — Ventilation of Health Care Facilities

The global standard for HVAC systems in healthcare buildings. Innotica ensures compliance with all operational requirements.

>20 air changes/hour in operating rooms

Automated control ensuring required airflow at all times.

Positive/negative differential pressure

Configurable pressure schemes by zone to prevent cross-contamination.

HEPA filtration with predictive alarms

Filter pressure drop monitoring for just-in-time replacement, not by calendar.

WELL Health-Safety

WELL Health-Safety Rating

The most rigorous human wellness standard. Certifies that your institution prioritizes the physical and mental health of patients and staff.

Superior indoor air quality

Continuous CO₂, particulate and VOC monitoring for an environment that accelerates recovery.

Thermal and lighting comfort

Circadian lighting and adaptive HVAC that synchronizes the patient's biological rhythm.

Emergency preparedness

Documented and monitored power backup protocols and failure response.

LEED / EDGE

LEED Healthcare and EDGE

Certifications that validate water, energy and material efficiency. Innotica provides the historical data and control needed to qualify.

Energy measurement and verification

Castor generates the per-system consumption reports required by the LEED protocol.

20-30% water consumption reduction

Perseo monitors water consumption and detects leaks that erode LEED scores.

Competitive differentiation

A LEED hospital attracts investors, talent and patients who prioritize responsible institutions.

In mission-critical infrastructure, there is zero margin for error. Technology must anticipate, not react.

How many critical systems does your clinic operate without centralized monitoring?

The first step is a technical assessment. We identify your vulnerabilities and design a phased implementation plan tailored to your budget.